Description
Testing Commissioning SwitchGear, Osama Abdel Aziz – Testing Commissioning SwitchGear, Testing Commissioning SwitchGear download, Osama Abdel Aziz – Testing Commissioning SwitchGear review, Testing Commissioning SwitchGear free torent
Osama Abdel Aziz – Testing Commissioning SwitchGear
Testing Commissioning SwitchGear
Reading Scheme
What you’ll learn
An overview of electrical transmission substation.
Basic concepts about circuit breaker and Types of circuit breaker.
Why don’t the distributor’s switchgear have the same capacity ?
The importance of having a dc ac voltage inside the distributor cells
The main rules for reading the scheam of current circuits and the reasons that lead to their explosion.
Understand the general philosophy of closing, triping and interlock circuits.
What is the working theory of anti-pumping relay and anti slam ?
Importance of trip circuit supervision in the early detection of circuit breaker faults.
The most important modifications in the scheam before the distributor enters the service.
Requirements
Basic Electrical Engineering knowledge
Description
Dear fellows,
This is the most comprehensive online training of MV switchgear. Here you will learn all thing about MV Switchgears.
In an electric power system, switchgear is composed of electrical disconnect switches, fuses or circuit breakers used to control, protect and isolate electrical equipment. Switchgear is used both to de-energize equipment to allow work to be done and to clear faults downstream.
we will go through the following topics
An overview of electrical transmission substation.
Basic concepts about circuit breaker and Types of circuit breaker.
Compartments of MV SWGR
Current Transformer
Voltage Transformer
Earthing Switch
Two-position Switch
Protection Relay
Operations of MV SWGR
Mechanical interlocks of MV SWGR
CB Trolley components
CB Mechanism
Why don’t the distributor’s switchgear have the same capacity ?
The importance of having a dc ac voltage inside the distributor cells
DC loop drawings
AC loop drawings
The main rules for reading the schema of current circuits and the reasons that lead to their explosion.
Understand the general philosophy of closing, triping and interlock circuits.
Upstream & downstream interlocks
What is the working theory of anti-pumping relay and anti slam ?
Importance of trip circuit supervision in the early detection of circuit breaker faults.
The most important modifications in the schema before the distributor enters the service.
The most important modifications before energize
Important note: All course contents are explained in the Arabic language
Who this course is for:
– Electrical engineers
– Student at the Faculty of Engineering, Electrical Department
– Electrical technician
Course content
Introduction
Introduction
Transformer Substation
components of electrical transmission substation.
Classification of circuit breaker
An overview of the distributor cells
What is the difference between incomer feeder& bus coupler and outgoing feeder ?
interview question
Current transformer schema
Current transformer explosions
Current transformer scheme part 1
Current transformer scheme part 2
DC&AC distribution inside the distributor cells
Indicating bulbs
interview question
Triping Schema
Trip philosophy
Anti-Pumping Relay And Anti slam
Trip Circuit Supervision
Incomer Scheme
Metering Scheme
Bus (Coupler – Riser) Scheme
Scheme Modification
Instructor
Osama Abdel Aziz
Bachelor of Electrical engineering (power & machines).
Osama Abdel Aziz
Hello,
I’m Osama Abdel Aziz
Electrical Power Systems Engineer
I Have
Bachelor of Degree in Electrical Power and Machines Engineering
i am work naw as protection enginner in EETC company
I share with you my academic and practical experience
I I find a real joy in teaching :).
Choosing an interesting and challenging field such as electrical engineering is a blessing and a gift I’m grateful For
Excellent knowledge and delivering the theory and practical concept with such an ease.
Trainer possesses strong competency in power plant and substation secondary system, scheme like busbar protection, breaker failure protection, substation automation, transformer differential, substation schemes lines/transformer/reactor/busbar, testing & commissioning of relays, scheme testing, testing of GIS/AIS substation equipment, testing of generator protection, on site trainings.