Sale!

Osama Abdel Aziz – Testing Commissioning Protection Relays

Original price was: ₹13,500.00.Current price is: ₹1,494.00.

-89%

Description

Testing Commissioning Protection Relays, Osama Abdel Aziz – Testing Commissioning Protection Relays, Testing Commissioning Protection Relays download, Osama Abdel Aziz – Testing Commissioning Protection Relays review, Testing Commissioning Protection Relays free torent
Osama Abdel Aziz – Testing Commissioning Protection Relays
Testing Commissioning Protection Relays

Commissioning RED 670 ( Line Differential Protection 87L – Distance Protection 21) and REF 615 Overcurrent Relay
What you’ll learn

Introduction to Protection Relays with Transmission line feeders
The Different Between Protection Schemes with Transmission line feeders
Install PCM Program and REF 615 Connectivity Package
Overcurrent Relay REF 615 Hardware Configuration
How change The Polarity of CT By using PCM Program
REF 615 Application Configuration
REF 615 Measurement Function Blocks
REF 615 Trip Logic Philosophy
Line Differential Distance Relay RED 670
RED 670 Connectivity Package
RED 670 Binary Input and Output
Transmute Current for Remote End Substation
RED 670 Application Configuration
Line Differential Function Block
Line Differential Trip Philosophy
Distance Protection Introduction
Power Swing and Fuse Failure Supervision
Trip Philosophy with Zone 1
Trip Philosophy with Zone( 2-3-4)
IT Received Trip From Remote End Substation
Communication Scheme (under & over ) Reach Scheme and Blocking Scheme
Current Reversal and Weak- End Feed Protection Function
Switch Onto Fault Function Block
Auto Re-closure
SAS Alarm ,Measurement and Disturbance Recorder

Requirements

The basic electrical principles
Description
Dear fellows,
This is the most comprehensive online training of Testing Commissioning Protection Relays . Here you will learn all thing about RED 670 and REF 615
RED 670 and REF 615 are the most common type of Protection Relays that you will find on the electrical network, due to their effectiveness and simplicity.
This course will give you an appreciation of how to commissioning this type of Protection Relays
we will go through the following topics

Introduction to Protection Relays with Transmission line feeders
The Different Between Protection Schemes with Transmission line feeders
Install PCM Program and REF 615 Connectivity Package
Overcurrent Relay REF 615 Hardware Configuration
How change The Polarity of CT By using PCM Program
REF 615 Application Configuration
REF 615 Measurement Function Blocks
REF 615 Trip Logic Philosophy
Line Differential Distance Relay RED 670
RED 670 Connectivity Package
RED 670 Binary Input and Output
Transmute Current for Remote End Substation
RED 670 Application Configuration
Line Differential Function Block
Line Differential Trip Philosophy
Distance Protection Introduction
Power Swing and Fuse Failure Supervision
Trip Philosophy with Zone 1
Trip Philosophy with Zone( 2-3-4)
IT Received Trip From Remote End Substation
Communication Scheme (under & over ) Reach Scheme and Blocking Scheme
Current Reversal and Weak- End Feed Protection Function
Switch Onto Fault Function Block
working theory of Auto Re-closure Function
SAS Alarm ,Measurement and Disturbance Recorder

Who this course is for:

Anyone interested in electrical engineering
Electrical undergraduates
Electrical graduates
Workers in the electrical power utility

Course content
Introduction

Introduction
The Different Between Protection Schemes

Overcurrent Relay REF 615

REF 615 manual
REF 615 Hardware Configuration
REF 615 Hardware Configuration 2
Polarity For CT
REF 615 Application Configuration
REF 615 Application Configuration 2
REF 615 Trip Logic
REF 615 Measurement

Line Differential Protection RED 670

RED 670 Connectivity Package
RED 670 Binary Input and Output
RED 670 CT and VT
Transmute Current for Remote End Substation
RED 670 Application Configuration
Signal Matrix For Analog Input SAMI
Line Differential Function Block
Line Differential Output Signal
Line Differential Trip

Distance Protection RED 670

Distance Protection Introduction
Phase Selection Function Block FDPSPDIS
Power Swing
Fuse Failure Supervision
Distance Schema
Trip Philosophy with Zone 1
Trip Philosophy with Zone( 2-3-4)
IT Received Trip From Remote End Substation
Communication Scheme (under & over ) Reach Scheme and Blocking Scheme
Communication Scheme Logic
Current Reversal and Weak- End Feed Protection
Question about Current Reversal
Weak- End Feed Logic
Switch Onto Fault
Auto Re-closure
Auto Re-Closure 2
SAS Alarm ,Measurement and Disturbance Recorder

Instructor
Osama Abdel Aziz
Bachelor of Electrical engineering (power & machines).
Hello,
I’m Osama Abdel Aziz
Electrical Power Systems Engineer
I Have
Bachelor of Degree in Electrical Power and Machines Engineering
i am work naw as protection enginner in EETC company
I share with you my academic and practical experience
I I find a real joy in teaching :).
Choosing an interesting and challenging field such as electrical engineering is a blessing and a gift I’m grateful For
Excellent knowledge and delivering the theory and practical concept with such an ease.
Trainer possesses strong competency in power plant and substation secondary system, scheme like busbar protection, breaker failure protection, substation automation, transformer differential, substation schemes lines/transformer/reactor/busbar, testing & commissioning of relays, scheme testing, testing of GIS/AIS substation equipment, testing of generator protection, on site trainings.