Sale!

Osama Abdel Aziz – Testing Commissioning 115 KV GIS

Original price was: ₹10,500.00.Current price is: ₹1,494.00.

-86%

Description

Testing Commissioning 115 KV GIS, Osama Abdel Aziz – Testing Commissioning 115 KV GIS, Testing Commissioning 115 KV GIS download, Osama Abdel Aziz – Testing Commissioning 115 KV GIS review, Testing Commissioning 115 KV GIS free torent
Osama Abdel Aziz – Testing Commissioning 115 KV GIS
Testing Commissioning 115 KV GIS

Reading Scheme OF GIS Drawing , Make Interface with Protection And Control Scheme
What you’ll learn

Wire Specification And Ferrouling System OF GIS Bays
SF6 GAS Scheme Diagram For All GIS Compartment
The Distribution OF DC Power Supply
Close Circuit Breaker From SAS Operating System and Emergency
The Different Between Service Position OF Circuit Breaker And Maintenance Position
Modification OF Maintenance Position In LCC Drawing
Synchronization Conditions For Circuit Breaker
The Important OF Trip Circuit Supervision For Circuit Breaker
Philosophy of Trip With Mechanical and Electrical Protection
High Impedance BusBar Protection Theory
The Important OF Using Early Make And Late Break Contact For Bus Disconnector
High Impedance BusBar Protection Zone (Discrimination Zone And Check Zone)
Philosophy of Trip For BusBar Protection
Circuit Breaker Fail Protection Theory
Philosophy of Trip For Circuit Breaker Fail Protection
Philosophy of Interlock To Ensure the Safe Operation OF The Stations
Philosophy of Interlock Between HV circuit Breaker And Earth Disconnector in Low Voltage Side
SF6 Alarm For All GIS Compartment
AC And DC Supervision Alarm

Requirements

The basic electrical principles
An interest in electrical utilities

Description
Dear fellows,
This is the most comprehensive online training of gas insulated substation . Here you will learn all thing about GIS.
Gas insulated substations are the most common type of substation that you will find on the electrical network, due to their effectiveness and simplicity.
This course will give you an appreciation of how to design,commissioning this type of substation and introduce you to all of the equipment’s that you will find in a typical gas insulated substation.
we will go through the following topics

Wire Specification And Ferrouling System OF GIS Bays
SF6 GAS Scheme Diagram For All GIS Compartment
The Distribution OF DC Power Supply
Close Circuit Breaker From SAS Operating System and Emergency
The Different Between Service Position OF Circuit Breaker And Maintenance Position
Modification OF Maintenance Position In LCC Drawing
Synchronization Conditions For Circuit Breaker
The Important OF Trip Circuit Supervision For Circuit Breaker
Philosophy of Trip With Mechanical and Electrical Protection
High Impedance BusBar Protection Theory
The Important OF Using Early Make And Late Break Contact For Bus Disconnector
High Impedance BusBar Protection Zone (Discrimination Zone And Check Zone)
Philosophy of Trip For BusBar Protection
Circuit Breaker Fail Protection Theory
Philosophy of Trip For Circuit Breaker Fail Protection
Philosophy of Interlock To Ensure the Safe Operation OF The Stations
Philosophy of Interlock Between HV circuit Breaker And Earth Disconnector in Low Voltage Side
AC And DC Supervision Alarm

Who this course is for:

Anyone interested in electrical engineering
Electrical undergraduates
Electrical graduates
Workers in the electrical utility industry
Electricians

Course content
Introduction

Substation Automation System (SAS)
Wire Specification
SF6 GAS Scheme Diagram
DC Power Supply
Interview Question

Circuit Breaker

CB Close Control
Maintenance Position
Close CB From Emergency
Close CB From SAS
CB Service Condition
Synchronization Conditions
Interview Question

Differential Protection _ Mechanical Protection

Trip Circuit Supervision
Protection Lock-out Relay Circuit
The Different Between 86T1 And 94T1
Modification OF Protection Scheme
Interview Question

High Impedance BusBar Protection

Differential Protection Theory For Busbar
Discrimination Zone
CT Circuit Zone – 1B,2B Differential Protection
Check Zone
Interview Question

Circuit Breaker Fail (CBF)

The Theory OF CBF
CBF Trip
Interview Question

Philosophy of Interlock

BusBAR Disconnector Interlock
D610 Interlock
Load Transfer
D610 – K614 Motor Control
D612 Interlock
D614 – K616 – K618 Interlock
Interview Question

Alarm

Circuit Breaker And Disconnector Alarm
AC And DC Supervision
SF6 Alarm
Interview Question

Instructor
Osama Abdel Aziz

Bachelor of Electrical engineering (power & machines).
Hello,
I’m Osama Abdel Aziz
Electrical Power Systems Engineer
I Have
Bachelor of Degree in Electrical Power and Machines Engineering
i am work naw as protection enginner in EETC company
I share with you my academic and practical experience
I I find a real joy in teaching :).
Choosing an interesting and challenging field such as electrical engineering is a blessing and a gift I’m grateful For
Excellent knowledge and delivering the theory and practical concept with such an ease.
Trainer possesses strong competency in power plant and substation secondary system, scheme like busbar protection, breaker failure protection, substation automation, transformer differential, substation schemes lines/transformer/reactor/busbar, testing & commissioning of relays, scheme testing, testing of GIS/AIS substation equipment, testing of generator protection, on site trainings.